Author : Nilesh V. Khalkar 1
Date of Publication :9th August 2017
Abstract: Now days renewable energy sources are very important for electrical power generation. In that condition wind power generation plays an important role in power system especially under integration of high penetration level of wind to grid, but at grid location having power quality problems like voltage sag, voltage swell, voltage fluctuations. As we know that most of the generator is induction generator (IG), so it requires more reactive power (VArs) from grid. In this paper according to aerodynamic aspects of wind farms, the major power quality problem that is voltage sag is mitigated by STATCOM .Wind turbine connected to squirrel cage induction generator(SCIG) is modeled by using MATLAB simulation with a fault condition to mitigate voltage sag and where STATCOM inject reactive power to increase power system stability
Reference :
-
[1] M. Q. Duong, K. H. Le, F. G. S. L. M. M. and R. E. Zich, "Comparison of Power Quality in Different Grid- Integrated Wind Turbines," in Harmonics and Quality of Power (ICHQP), 2014 IEEE 16th International Conference on, Bucharest , 2014
[2] A. R. Tiwari, A. J. Shewale, A. R. Gagangras and N.M. Lokhande, "Comparison of various Wind Turbine Generators," Multidisciplinary Journal of Research in Engineering and Technology, vol. 1, no. 2, pp. 129-135, 2014.
[3] Kadam D. P. and Dr. Kushare B. E. “Dynamic Behaviour of Large Scale Wind Farm”, International Journal of Electrical Engineering, Volume 5, Number 6, PP. 757 764, 2012.
[4] Wenyong Guo, Liye Xiao, Shaotao Dai, Xi Xu, Yuanhe Li and Yifei Wang, 2015. “Evaluation of the Performance of BTFCLs for Enhancing LVRT Capability of DFIG” IEEE Transaction On Power Electronics, 30(7): 3623-3636.
[5] N.G. Hingorani, L. Gyugyi, Understanding FACTS: Concepts and Technology of Flexible AC Transmission Systems, New York, Wiley-IEEE Press, 1999
[6] M. G. Sugirtha, M. E. P. L. M. E. and P. D. , "Analysis of Power Quality Problems in Grid Connected Wind Power Plant," in Recent Advancements in Electrical, Electronics and Control Engineering (ICONRAEeCE), 2011 International Conference on, Sivakasi, 2011.
[7] P. S. M. I. and Y.-J. S. , "Power Quality Impact of Wind Turbine Generators on the Electrical Grid," in Energytech, 2012 IEEE , Cleveland, OH , 2012 .
[8] Kishor V. Bhadane1 Dr. M. S. Ballal2 Dr. R. M. Moharil, Investigation for Causes of Poor Power Quality in Grid Connected Wind Energy- A Review,"978-1-4577-0547- 2/12/31:002012IEEE:
[9] R. C.Dugan, M. F. McGranaghan, S. Santoso and H. W. Beaty, Electrical Power Systems Quality", McGraw-Hill, 2011.