Open Access Journal

ISSN : 2394 - 6849 (Online)

International Journal of Engineering Research in Electronics and Communication Engineering(IJERECE)

Monthly Journal for Electronics and Communication Engineering

Open Access Journal

International Journal of Engineering Research in Electronics and Communication Engineering(IJERECE)

Monthly Journal for Electronics and Communication Engineering

ISSN : 2394-6849 (Online)

Pulse Rate Monitor At Pinna

Author : Atheeth S 1 Bhargav Anur Krishnaprasad 2 S B Bhanu Prashanth 3

Date of Publication :15th June 2017

Abstract: The pulse sensor designed in this work, is in the form of a wearable clip, and it is within a circular die that measures less than 1.2cm in diameter. Sensor is backed by a software algorithm, which tracks the peak of pulse signals with 95% accuracy. Pulse rate values from this sensor shows a difference of 1 or 2 beats per minute (BPM), on comparison with chosen commercial devices.

Reference :

    1. X. Zhu et al., “Real-time monitoring of respiration rhythm and pulse rate during sleep,” IEEE Trans. Biomed. Eng., vol. 53, no. 12, pp. 2553–2563, 2006.
    2. C. Lin, K. Chen, and S. Huang, “Main Menu New Reflector Materials in SMD-LED Package Application Main Menu,” no. 195, pp. 571–574.
    3. Y. Savchenko, D. Beklemishev, and A. Pereverzev, “Building a Highly Sensitive IR Sensor for Short- Range Optical Location,” pp. 449–451, 2016.
    4. C. Kolacinski et al., “Dedicated Chip for Pulse Oximetry Measurements,” pp. 1–4, 2016.
    5. M. E. Raypah, B. K. Sodipo, M. Devarajan, and F. Sulaiman, “Estimation of Luminous Flux and Luminous Efficacy of Low-Power SMD LED as a Function of Injection Current and Ambient Temperature,” IEEE Trans. Electron Devices, vol. 63, no. 7, pp. 2790–2795, 2016
    6. C. Lin, K. Chen, and S. Huang, “Evaluation of the Reliability Performance about New Developed UP Reflector in Mid / High Power SMD LED Applications,” pp. 341–344, 2016.
    7.  W. Jang, Z. Ku, J. Park, and A. Urbas, “Optimal design of IR Sensor ’ s Spectral Bands for Material Classification,” pp. 278–280, 2016
    8.  S. Engelberg, “Calibration-free pulse oximetry based on two wavelengths in the infrared - a preliminary study,” Sensors (Basel)., vol. 14, no. 4, pp. 7420–7434, 2014.
    9. X. Zhu et al., “Real-time monitoring of respiration rhythm and pulse rate during sleep,” IEEE Trans. Biomed. Eng., vol. 53, no. 12, pp. 2553–2563, 2006.
    10. N. Constant, T. Wang, and K. Mankodiya, “Pulseband: A hands-on tutorial on how to design a smart wristband to monitor heart-rate,” 2015 IEEE Virtual Conf. Appl. Commer. Sensors, pp. 1–4, 2015.
    11. D. Kaur, S. Kumar, and S. Sharma, “Online Graphical Display of Blood Oxygen Saturation and Pulse Rate,” vol. 2, no. 6, pp. 1–5, 2011.

Recent Article