Implementation of Non-Invasive Blood Glucose Monitoring System

Author : Gorochna.M 1 Rekha. R 2 Shwetha Baliga 3

Date of Publication :5th August 2022

Abstract: In the case of diabetes, measuring blood sugar levels is made challenging by the need to pick one's finger. Laboratory testing and one-touch glucometers are intrusive procedures that increase the risk of blood-related illnesses. In the current work, we propose a novel edge device with IoMT (Internet-of-Medical-Things) capabilities for precise, non-invasive blood glucose monitoring to solve this crucial issue. In this study, a NIR (Near-Infrared) spectroscopy method is used to identify the glucose molecule in human blood at two wavelengths (940 nm, and 1300 nm). The cutting-edge gadget known as iGLU is based on high-accuracy ML (Machine Learning) models and NIR spectroscopy. For accurate measurement, a DNN (Deep Neural Network) model and an ideal multiple polynomial regression model have been provided. An open IoT platform is used to evaluate the proposed gadget, and blood glucose levels are then saved there for endocrinologist remote monitoring. For device validation, the blood glucose measurements obtained from the invasive device and the projected blood glucose levels have been compared. The AvgE (Average Error) & MARD (Mean Absolute Relative Difference) of the predicted blood glucose concentration levels were determined to be 4.66 percent and 4.61 percent, respectively. There is a 0.81 regression coefficient. An accurate and economical solution for smart healthcare is offered by the suggested spectroscopic non-invasive gadget.

Reference :

    1. Ali, H., Bensaali, F., & Jaber, F. (2017). A novel approach to non-invasive blood glucose monitoring based on transmittance and refraction of visible laser light. IEEE Access, 5, 9163-9174.
    2. Zhao, S., Tao, W., He, Q., & Zhao, H. (2017, June). A new approach to non-invasive blood glucose measurement based on 2 dimensions photoacoustic spectrum. In 2017 First International Conference on Electronics Instrumentation & Information Systems (EIIS) (pp. 1-5). IEEE.
    3. Arefin, M. S., Khan, A. H., & Islam, R. (2018, December). Non-invasive blood glucose determination using near-infrared LED in diffused reflectance method. In 2018 10th International Conference on Electrical and Computer Engineering (ICECE) (pp. 93-96). IEEE.
    4. Reddy, P. S., & Jyostna, K. (2017, January). Development of smart insulin device for noninvasive blood glucose level monitoring. In 2017 IEEE 7th International Advance Computing Conference (IACC) (pp. 516-519). IEEE.
    5. Choi, H., Luzio, S., Beutler, J., & Porch, A. (2017, June). Microwave noninvasive blood glucose monitoring sensor: Human clinical trial results. In 2017 IEEE MTT-S International Microwave Symposium (IMS) (pp. 876-879). IEEE.
    6. Dantu, V., Vempati, J., & Srivilliputhur, S. (2014, August). Non-invasive blood glucose monitor based on spectroscopy using a smartphone. In 2014 36th annual international conference of the IEEE engineering in medicine and biology society (pp. 3695-3698). IEEE.
    7. Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2014, February). Near-infrared LED-based non-invasive blood glucose sensor. In 2014 International Conference on Signal Processing and Integrated Networks (SPIN) (pp. 591-594). IEEE.
    8. Chowdhury, S. R., Nandi, B., & Mondal, P. (2018, June). Non-invasive blood insulin and glucose monitoring system based on near-Infrared spectroscopy with remote data logging. In 2018 IEEE 31st International Symposium on Computer-Based Medical Systems (CBMS) (pp. 274-279). IEEE.
    9. Hofmann, M., Fersch, T., Weigel, R., Fischer, G., & Kissinger, D. (2011, May). A novel approach to non-invasive blood glucose measurement based on RF transmission. In 2011 IEEE International Symposium on Medical Measurements and Applications (pp. 39-42). IEEE.
    10. Abd Salam, N. A. B., bin Mohd Saad, W. H., Manap, Z. B., & Salehuddin, F. (2016). The evolution of a non-invasive blood glucose monitoring system for personal application. Journal of Telecommunication, Electronic and Computer Engineering (JTEC), 8(1), 59-65.
    11. Sarkar, K., Ahmad, D., Singha, S. K., & Ahmad, M. (2018, December). Design and implementation of a noninvasive blood glucose monitoring device. In 2018 21st International Conference of Computer and Information Technology (ICCIT) (pp. 1-5). IEEE.
    12. Yu, Y., Huang, J., Zhu, J., & Liang, S. (2020). An accurate noninvasive blood glucose measurement system using a portable near-infrared spectrometer and transfer learning framework. IEEE Sensors Journal, 21(3), 3506-3519.
    13. Anand, P. K., Shin, D. R., & Memon, M. L. (2020). Adaptive Boosting Based Personalized Glucose Monitoring System (PGMS) for Non-Invasive Blood Glucose Prediction with Improved Accuracy. Diagnostics, 10(5), 285