ARM Based Smart Drinking Water Distribution System

Author : J.Krishna Chaithanya 1 Dr. T. Ramashri 2

Date of Publication :7th March 2017

Abstract: The aim of this project is to implement a smart drinking water distribution system through smart card and detecting contamination of water so that people in rural, slums and also in area where there is scarcity of ground water. Not only providing safe and clean water through this system we can also reduce the wastage of water and crowding near the water tankers. Our approach is to design a system which determines the purity of supplied water and with the help of a smart card setup controls the amount of quantity to each member and also controls the illegal supply of water, thereby organizing the supply of water with lightweight implementation and reliable long time operation. This system adopts the ARM based controller to read the inputs from the sensor and determine the contamination levels if any and then provide the supply of water, Smart card system and GSM wireless network. The system can run well under the unattended operation, great reducing the intensity of work and making the water monitoring more secure, reliable and economical.

Reference :

  1. [1] Theofanis P. Lambrou, Christos C. Anastasiou, Christos G. Panayiotou, and Marios M. Polycarpou ‖ A Low-Cost Sensor Network for RealTimeMonitoring and Contamination Detection in Drinking Water Distribution Systems.‖

    [2] Dongjiang Li, Weipeng Zhao, Lihua Zhang and Bo zhangSchool of Control And Computer Engineering “ARM-based Design And Realization of Water Well Monitoring Terminal‖.

    [3] Gurkan Tuna, Orhan Arkoc, and Kayhan Gulez ‖Continuous Monitoring of Water Quality Using Portable and Low-Cost Approaches‖.

    [4] By Peter Corke, Fellow IEEE, Tim Wark, Member IEEE, Raja Jurdak, Member IEEE, ―Environmental Wireless Sensor Networks‖.

    [5] C. C. Anastasiou1, P. Grafias, T. P. Lambrou, A. Kalli1 and C. Onisiphorou ―Use of holding tanks and their effect on the quality of potable water in households; the case study of cyprus‖ [6] J. Hall et al., ―On-line water quality parameters as indicators of distribution system contamination,‖ J. Amer. Water Works Assoc., vol. 99, no. 1, pp. 66–77, 2007

    [7] M. V. Storey, B. Gaag, and B. P. Burns, ―Advances in on-line drinking water quality monitoring and early warning systems,‖ Water Res., vol. 45, no. 2, pp. 741– 747, Jan. 2011.

    [8] D. Hart, S. McKenna, K. Klise, V. Cruz, and M. Wilson, ―CANARY: A water quality event detection algorithm development tool,‖ in Proc. World Environ. Water Resour. Congr., 2007.

    [9] G. Tuna and K. Gulez, ―Energy harvesting techniques for industrial wireless sensor networks,‖ in Industrial Wireless Sensor Networks: Applications, Protocols, Standards, and Products. Cleveland, OH, USA: CRC Press, 2013.

    [10]Whittle, M. Allen, A. Preis, and M. Iqbal, ―Sensor networks for monitoring and control of water distribution systems,‖ in Proc. 6th Conf. Structural Health Monitor. Intell. Infrastruct., 2013. [42] KAPTA 3000-AC4 Product Technical Datasheet, KAPTA, Boulder, CO, USA, 2014.

    [11]B. H. Tangenaet al., ―A novel approach for early warning of drinking water contamination events,‖ in Proc. Water Contaminate. Emergencies Conf., 2011, pp. 13–31.

    [12]M. J. Moorcroft, J. Davis, and R. G. Compton, ―Detection and determination of nitrate and nitrite: A review,‖ Talanta, vol. 54, no. 5, pp. 785–803, Jun. 21, 2001.

    [13]M. T. Downes, ―An improved hydrazine reduction method for the automated determination of low nitrate levels in freshwater,‖ Water Res., vol. 12, no. 9, pp. 673–675, 1978.

    [14]K. Sundara-Rajan, L. Byrd, and A. V. Mamishev, ―Moisture content estimation in paper pulp using fringing field impedance spectroscopy,‖ IEEE Sensors J., vol. 4, no. 3, pp. 378–383, Jun. 2004

    [15]S. M. Radke and E. C. Alocilja, ―A microfabricated biosensor for detecting foodborne bioterrorism agents,‖ IEEE Sensors J., vol. 5, no. 4, pp. 744–750, 2005.

    [16]S. C. Mukhopadhyayet al., ―Low cost sensing system for dairy products quality monitoring,‖ in Proc. IEEE Instrum. Meas. Technol. Conf. (IMTC), May 2005, vol. 1, pp. 244–249.

    [17]V. Mamishevet al., ―Interdigital sensors and transducers,‖ in Proc. IEEE Sens. Appl. Symp., May 2004, vol. 92, no. 5, pp. 808–845.

    [18]J. W. H. Adam, ―Health aspects of nitrate in drinking water and possible means of denitrifications,‖ Water SA, vol. 6, no. 2, pp. 79–84, 1980.

    [19]S. X. Liu, S. W. Hermanowicz, and M. Peng, ―Nitrate removal from drinking water through the use of encapsulated microorganisms in alginate beads,‖ Environment. Technol., vol. 24, no. 9, pp. 1129–1134, 2003.

    [20]M. Fan, C. C. Willhite, and S. A. Book, ―Evaluation of the nitrate drinking-water standard with reference to infant methemoglobinemia and potential reproductive toxicity,‖ Regul. Toxicol. Pharmacol., vol. 7, no. 2, pp. 135–148, Jun. 1987.


Recent Article